LC - LC Duplex Push Pull
Get Latest PricePayment Type: | L/C,T/T,Discussed |
Incoterm: | FOB,CIF,EXW,DDU,Express Delivery |
Transportation: | Ocean,Land,Air,Express |
Port: | Shenzhen,Shanghai |
Supply Type: | Original Manufacturer |
Payment Type: | L/C,T/T,Discussed |
Incoterm: | FOB,CIF,EXW,DDU,Express Delivery |
Transportation: | Ocean,Land,Air,Express |
Port: | Shenzhen,Shanghai |
Supply Type: | Original Manufacturer |
Content Introduction: The LC-LC Duplex Push Pull fiber optic patch cord offers high-density connectivity for data centers and enterprise networks. It features a uniboot design integrating duplex channels within a single cable jacket. This push-pull mechanism connector simplifies insertion and removal in congested rack environments. It supports high-speed data transmission for 10G, 40G, and 100G applications across both multimode and single-mode fibers.
Product Features:
Space-saving uniboot construction consolidates two fibers into one cable.
Push-pull tabs enable easy single-handed operation during connections.
Low insertion loss ≤0.3dB ensures optimal signal integrity.
High return loss ≥50dB minimizes reflective interference effectively.
Bend-insensitive fiber (e.g., Corning) reduces attenuation in tight routes.
LSZH or PVC jacketing options meet diverse fire safety requirements.
Robust zirconia ceramic ferrules provide precise alignment durability.
IEC/TIA standards compliance guarantees reliable performance.
Polarity reversal capability simplifies configuration flexibility.
Mating cycles exceed 500 for extended operational lifespan.
Operating temperature range spans -40°C to +85°C.
LC/APC Simplex Fiber Patch Cable Specifications: | |||
Fiber Connector | Push/Pull Tab Uniboot to LC Push/Pull Tab LC Uniboot | Fiber Type | SM:Yellow/Blue/White; OM1&OM2: Orange; OM3:Aqua; |
OM4:Aqua/Violet/ Magenta | |||
Cable OD&Jacket | 1.6mm/1.7mm,/1.8mm/2.0 mm PVC/LSZH | Fiber Counts | 2 Fibers |
Insertion Loss | ≤0.3dB(IEC Grade C) | Return Loss | SM UPC ≥ 50dB(min) SM APC ≥ 60dB(min) MM PC ≥ 35dB(min) |
≤0.12dB(IEC Grade B) | |||
Pull-out Force | 100N | Durability | 500 Cycles |
AB Polarity Switchable | Available | Operating Temperature | -40 to + 85°C |
Geometric Specification( if Customer requested) | |||
Items | Parameter | ||
Polishing | PC | APC | |
ROC | LC | 7~ 25 | 5 ~ 12 |
Apex Offset | ≤ 50 | ||
Fiber Spherical Height | ±100 | ||
Angle | ± 0.5 | 8 ± 0.5 |